Bosch Fault code Bosch
A1

Heating pump builds no pressure

Blocking: it retries by itself

The heating pump builds no pressure in the circuit (A1 with 281 on the display): the cause is the water pressure, air in the system, a closed valve or the pump itself. It is a blocking fault: the boiler stops and restarts by itself as soon as the cause is gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the water pressure on the gauge: normally between 1 and 2 bar. Too low? Top up while the boiler is cold, as your installer showed you.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show A1?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code A1

The small number shown beside the code tells which.

A1
281

The heating pump does not generate any pressure

Blocking: it retries by itself GC7000iW

The boilers that show this code

What our technician checks

  • The heating system water pressure
  • The isolating valves, to be opened
  • Purging the boiler (service function 2.2C)
  • The heating pump: get it running, replace if needed

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.

281