Boiler temperature limiter has tripped
Breakdown: the boiler is stopped
One of the boiler's temperature limiters has tripped, the flue gas one or the heat exchanger one; a closed valve in the heating circuit, water pressure that is too low or air in the boiler may be the cause, as may a faulty limiter or cable. The boiler first stops and restarts by itself if the cause goes away; if the fault lasts, it becomes a locking fault and the boiler only restarts after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the water pressure on the gauge: normally between 1 and 2 bar. Too low? Top up with water while the boiler is cold, as your installer showed you.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 224?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 224
The meaning depends on the boiler: find yours below.
The flue gas temperature limiter or the heat exchanger temperature limiter…
The boilers that show this code
What our technician checks
- The valve position in the heating circuit, opened if needed
- The water pressure, topped up to the set pressure
- The heat exchanger temperature limiter and its cable, replaced if needed
- The flue gas temperature limiter and its cable, replaced if needed
- Bleeding the boiler with service function 4-A1