Water flow too low during hot water production
Blocking: it retries by itself
During hot water production, the water flow in the boiler's circuit drops below the minimum in four attempts in a row, for example because of a closed valve, scale or sludge, air, a faulty pump or too low a water pressure. The boiler then blocks hot water production for a time set in the boiler, heating remains possible, and hot water is then released again by itself.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check the system pressure on the display: below 1.0 bar, top up with water or call us.
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 981?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 981
The meaning depends on the boiler: find yours below.
Flow rate fell below the minimum during DHW production:
What our technician checks
- The cylinder's shut-off valves, fully open
- The hydraulic scheme set, corrected if needed
- Full venting of the heating circuit (venting program)
- The quick-action air vents, always open and not leaking, replaced if needed
- The set system pressure
- The circulation pump, replaced if needed