Viessmann Fault code Viessmann
980

Water flow too low before hot water production

Blocking: it retries by itself

Before making hot water, the boiler measures too little water flow in its circuit, even after four attempts over about twenty minutes, for example because of a closed valve, scale or sludge, air, a faulty pump or too low a water pressure. It then blocks hot water production for a time set in the boiler, heating remains possible, and hot water is then released again by itself.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check the system pressure on the display: below 1.0 bar, top up with water or call us.
  3. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 980?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 980

The meaning depends on the boiler: find yours below.

980

Flow rate fell below the minimum before the start of DHW production:

Blocking: it retries by itself Vitodens 100-W B1HF

What our technician checks

  • The cylinder's shut-off valves, fully open
  • The hydraulic scheme set, corrected if needed
  • Full venting of the heating circuit (venting program)
  • The quick-action air vents, always open and not leaking, replaced if needed
  • The set system pressure
  • The circulation pump, replaced if needed

Related codes