Viessmann Fault code Viessmann
7

Hot water temperature sensor open circuit

Blocking: it retries by itself

The boiler no longer gets a signal from the sensor that measures the hot water temperature (open circuit). It makes no more hot water until the sensor or its wiring is repaired.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 7?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 7

The meaning depends on the boiler: find yours below.

7

Open circuit of the DHW temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HF

What our technician checks

  • The hot water setting in the commissioning wizard
  • The hot water temperature sensor (terminal 2)
  • The voltage at the HBMU sensor input: 3.3 V with the sensor disconnected
  • The faulty part, to be replaced