Flame signal (ionisation) out of range
Breakdown: the boiler is stopped
The ionisation current, the electrical signal the boiler uses to watch its flame, is outside the valid range. The burner goes to fault and the boiler stops until it is reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 69?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 69
The meaning depends on the boiler: find yours below.
Ionisation current outside the valid range
What our technician checks
- The insulating ring, which must not touch the electrode ceramic
- The combined gas valve, with the burner at lowest output for about 4 minutes (service menu "b.6")
- The HBMU central electronic module, replaced if the fault shows in that test
- Burner modulation from lowest to highest output ("b.6")
- The inlet strainer, if the fault shows while modulating
- The fan unit, replaced if needed