Viessmann Fault code Viessmann
67

Flame signal (ionisation) out of range

Breakdown: the boiler is stopped

The ionisation current, the electrical signal the boiler uses to watch its flame, is outside the valid range. The burner goes to fault and the boiler stops until it is reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Check that the boiler's gas supply valve is open.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 67?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 67

The meaning depends on the boiler: find yours below.

67

Ionisation current outside the valid range

Breakdown: the boiler is stopped Vitodens 100-W B1HF

What our technician checks

  • The gas supply: pressure and gas flow monitor
  • The combined gas valve and its inlet strainer
  • The ionisation electrode or the ignition and monitoring electrode: distance to the burner gauze
  • Fouling of the electrode and the burner gauze
  • The fan unit, replaced if the fault persists