No flame when the burner starts
Breakdown: the boiler is stopped
When the burner starts, the boiler sees no flame, or too weak a flame: the burner goes to fault and the boiler stops until it is reset. If it happens a fifth time, the boiler shows code 359 and locks out.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas supply valve is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 65?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 65
The meaning depends on the boiler: find yours below.
No flame signal or flame signal too weak when the burner starts
What our technician checks
- The gas supply: pressure and gas flow monitor
- The combined gas valve
- No condensate build-up in the system, and the condensate drain
- The ionisation electrode or the ignition and monitoring electrode, and its cable
- The ignition and the cables between the igniter and the ignition electrode
- The gap and fouling of the ignition electrode
- The ignition electrode ceramic (cracks)