Room temperature sensor open circuit
Blocking: it retries by itself
The boiler no longer gets the temperature from the room sensor (open circuit), the one in a Vitotrol remote control or a separate sensor in a room. It keeps heating, but without taking the room temperature into account.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show 57?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 57
The meaning depends on the boiler: find yours below.
Open circuit of the room temperature sensor
What our technician checks
- The remote control setting made at commissioning
- The plug and cable of the heating circuit's external room sensor
- Without an external sensor: the Vitotrol control unit, to be replaced