Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Viessmann Fault code Viessmann
464

Flame signal too low during calibration

Breakdown: the boiler is stopped

During the automatic calibration of its combustion, shortly after the burner starts, the boiler measures an ionisation current (the flame signal) that is too low, too far from the previous value: the electrode or its cable, dust in the air, flue gas getting back into the combustion air or built-up condensate can be the cause. The burner locks out and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.
  3. Reset the boiler once only.
  4. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show 464?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 464

The meaning depends on the boiler: find yours below.

464

Ionisation current too low during calibration

Breakdown: the boiler is stopped Vitodens 100-W B1HF

What our technician checks

  • The ionisation electrode, or ignition and monitoring electrode, and its connecting cable
  • The plug connections, free of loose contacts
  • Dust in the combustion air (building work, for example)
  • The flue system, and any flue gas recirculation to be eliminated
  • Condensate building up in the system
  • The HBMU central electronic module, to be replaced if the fault persists after unlocking
  • The causes of deposits in the boiler room and flue system (detergents, cleaning or personal care products)
  • After replacing the burner gauze and the electrode, cleaning of the fan unit, the gas-air duct and the venturi extension

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.