Ionisation current shorted to earth
Breakdown: the boiler is stopped
The ionisation current, which the boiler uses to monitor its flame, is shorted to earth, or the central electronic module is faulty. For safety, the burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 387?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 387
The meaning depends on the boiler: find yours below.
Short circuit to earth of the ionisation current
What our technician checks
- The ionisation electrode or ignition/monitoring electrode and its connecting cable
- The HBMU central electronic module, to be replaced if the fault persists