Flame lost just after ignition
Breakdown: the boiler is stopped
The flame goes out just after it has formed, during the ignition safety time. The burner goes into fault; according to the maker's manual, the fifth time it happens code 380 appears and the boiler locks out until a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Check that the boiler's gas tap is open.
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 369?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 369
The meaning depends on the boiler: find yours below.
Loss of flame immediately after its formation (during the safety time)
What our technician checks
- The gas supply: gas pressure and gas flow limiter
- Flue gas recirculation in the flue and air intake ducts
- The ionisation electrode or ignition/monitoring electrode: distance to the burner grid and fouling