Viessmann Fault code Viessmann
361

No or weak flame signal at start-up

Breakdown: the boiler is stopped

When the burner starts, the boiler detects no flame, or too weak a flame signal. For safety, the burner locks out and the boiler only starts again after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.
  4. Keep paint, solvent and cleaning product fumes, and building dust, away from the boiler.

Does your boiler show 361?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 361

The meaning depends on the boiler: find yours below.

361

The flame signal is absent or too weak when the burner starts

Breakdown: the boiler is stopped Vitodens 100-W B1HF

What our technician checks

  • The ionisation electrode or ignition/monitoring electrode and its connecting cable
  • The plug connections (loose contacts)
  • The source of deposits on the electrodes in the boiler room and the flue system (detergents, cleaning or personal care products)