Flame signal present before ignition
Breakdown: the boiler is stopped
When the burner starts, the boiler already sees a flame signal: the cause may be a condensate build-up, the electronics or the ignition transformer. For safety, the burner locks out and the boiler only starts again after a reset.
What you can do
- Write down the code shown and the boiler model (on the rating plate).
- Reset the boiler once only.
- If the code comes back, do not keep trying and do not take anything apart: call us.
Does your boiler show 355?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code 355
The meaning depends on the boiler: find yours below.
Condensate accumulation or reference check of the analogue signal: flame signal already…
What our technician checks
- If condensate has built up: the insulating ring, the insulation block, the electrodes and the burner grid, to be replaced
- The HBMU central electronic module, to be replaced
- The ignition transformer and ignition cable, replaced if needed
- Removing the fan unit before opening the burner, with the electronics protected from water