Viessmann Fault code Viessmann
352

Combustion CO limit exceeded

Breakdown: the boiler is stopped

The boiler has detected a carbon monoxide (CO) level in its combustion above its limit. For safety, the burner locks out and the boiler only starts again after a reset: our technician needs to check the whole flue gas path (leaks, water pocket, narrowing, blockage).

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Smell of flue gas in the room? Switch the boiler off, air the room and close the doors to the living areas, then call us.
  3. Do not reset the boiler: call us.

Does your boiler show 352?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 352

The meaning depends on the boiler: find yours below.

352

Combustion CO limit value exceeded

Breakdown: the boiler is stopped Vitodens 100-W B1HF

What our technician checks

  • The whole flue gas path: leaks
  • Flue gas build-up caused by a water pocket (too shallow a slope)
  • A narrowing or a blockage in the flue
  • Servicing the flue system, if needed