Viessmann Fault code Viessmann
13

Outdoor temperature sensor open circuit

Blocking: it retries by itself

The boiler no longer gets the temperature from the outdoor sensor (open circuit). It keeps heating, but as if it were 0 °C outside, whatever the weather.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 13?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 13

The meaning depends on the boiler: find yours below.

13

Open circuit of the outside temperature sensor

Blocking: it retries by itself Vitodens 100-W B1HF

What our technician checks

  • The operating mode set in the commissioning wizard
  • The outdoor sensor and its wiring (terminal 4)
  • The voltage at the HBMU sensor input: 3.3 V with the sensor disconnected
  • The faulty part, to be replaced