Refrigerant pressure outside operating range
Breakdown: the boiler is stopped
On an aroTHERM (VWL ../2 A, ../3 A) heat pump, the refrigerant pressure is outside its operating range: too much or too little refrigerant, non-condensable particles in the circuit, a faulty electronic expansion valve, 4-way valve or temperature sensor, too high a water flow rate or poor heat exchange. This is a refrigerant circuit fault: the heat pump no longer works normally, and only a trained and certified technician may work on this circuit.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.554?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.554
The meaning depends on the boiler: find yours below.
Refrigerant pressure outside service range
What our technician checks
- The refrigerant charge (too much or too little)
- Non-condensable particles in the refrigerant circuit
- The electronic expansion valve
- Early expansion of the liquid refrigerant (pressure drop in the refrigerant circuit)
- The water flow rate (above the set maximum)
- Heat exchange at the plate heat exchanger and the finned tube heat exchanger
- The 4-way valve
- The temperature sensors