Refrigerant pressure too low
Breakdown: the boiler is stopped
On an aroTHERM (VWL ../2 A, ../3 A) heat pump, the refrigerant pressure is too low: too little refrigerant, too little air flow, no defrosting, a faulty condensate collector heater, a faulty 4-way valve or a faulty electronic expansion valve. This is a refrigerant circuit fault: the heat pump no longer works normally, and only a trained and certified technician may work on this circuit.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.539?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.539
The meaning depends on the boiler: find yours below.
Refrigerant pressure too low
What our technician checks
- The refrigerant charge (too little, leak)
- The air flow through the evaporator
- Defrosting
- The condensate collector heater
- The 4-way valve
- The electronic expansion valve motor and its connection