Vaillant Fault code Vaillant
F.536

Compressor outlet temperature too high

Breakdown: the boiler is stopped

On an aroTHERM (VWL ../2 A, ../3 A) heat pump, the temperature at the compressor outlet is above the permitted maximum, which limits operation: too little refrigerant, a faulty sensor, a faulty electronic expansion valve or a blocked heat exchanger. This is a refrigerant circuit fault: the heat pump no longer works normally, and only a trained and certified technician may work on this circuit.

What you can do

  1. Write down the code shown and the heat pump model (on the rating plate).
  2. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show F.536?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code F.536

The meaning depends on the boiler: find yours below.

F.536

Compr. outlet temp. too high

Breakdown: the boiler is stopped aroTHERM VWL ../2 A, ../3 A

What our technician checks

  • The refrigerant charge (too little)
  • The compressor outlet sensor and its connection to the main PCB
  • The electronic expansion valve
  • Early expansion of the liquid refrigerant (pressure drop in the refrigerant circuit)
  • The heat exchanger (blocked)