Compressor outlet temperature too high
Breakdown: the boiler is stopped
On an aroTHERM (VWL ../2 A, ../3 A) heat pump, the temperature at the compressor outlet is above the permitted maximum, which limits operation: too little refrigerant, a faulty sensor, a faulty electronic expansion valve or a blocked heat exchanger. This is a refrigerant circuit fault: the heat pump no longer works normally, and only a trained and certified technician may work on this circuit.
What you can do
- Write down the code shown and the heat pump model (on the rating plate).
- Does the code stay on or come back? Do not take anything apart: call us.
Does your boiler show F.536?
Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.
* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.
The variants of code F.536
The meaning depends on the boiler: find yours below.
Compr. outlet temp. too high
What our technician checks
- The refrigerant charge (too little)
- The compressor outlet sensor and its connection to the main PCB
- The electronic expansion valve
- Early expansion of the liquid refrigerant (pressure drop in the refrigerant circuit)
- The heat exchanger (blocked)