Skip to Content
+32 15 62 70 80 info@ecowatt.be Mon-Thu 07:30-17:00, Fri 07:30-13:30 Request a repair
Repair
Junkers Fault code Junkers
0Y

Flow temperature above 95 °C

Blocking: it retries by itself

The water the boiler sends to the heating has gone above 95 °C: the water pressure, a closed valve or the heating pump may be the cause, and the code can also appear without any fault when all the radiator valves close at the same time. It is a blocking fault: the boiler stops for a while and restarts by itself once the fault has gone.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Have you closed the thermostatic valves on all the radiators, to air the rooms for example? Open them again.
  3. Check the water pressure on the gauge: normally between 1 and 2 bar. Too low? Top up with water while the boiler is cold, as your installer showed you.
  4. Does the code stay on or come back? Do not take anything apart: call us.

Does your boiler show 0Y?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code 0Y

The small number shown beside the code tells which.

0Y
276

The temperature at the flow temperature sensor is > 95 °C

Blocking: it retries by itself Cerapur ZWB-4

The boilers that show this code

What our technician checks

  • The heating system's operating pressure
  • The isolating valves, opened
  • The heating pump, tested with service function t3
  • The pump's connecting cable
  • Getting the pump going again, or replacing it
  • The pump output or pump curve setting

Related codes

From the manufacturer's service manuals for Belgium. Each appliance has its own features: if in doubt, call us.