Bosch Fault code Bosch
Fb

Flame detected after the gas is shut off

Breakdown: the boiler is stopped

The boiler has shut off the gas, but it still detects a flame. It is a locking fault: for safety, the boiler stops and only restarts after a reset.

What you can do

  1. Write down the code shown and the boiler model (on the rating plate).
  2. Reset the boiler once only.
  3. If the code comes back, do not keep trying and do not take anything apart: call us.

Does your boiler show Fb?

Repair visit: 180 € excl. VAT (190.80 € incl. 6 % VAT*), first hour included, parts excluded.

* 6 % VAT: work on a private home more than 10 years old, invoiced to a private person. Without a written objection within a month of the invoice, you confirm that these conditions are met; otherwise the VAT is 21 % and the responsibility is yours.

The variants of code Fb

The small number shown beside the code tells which.

Fb
365

After gas shut-off: flame is detected

Breakdown: the boiler is stopped GC7000iW

The boilers that show this code

What our technician checks

  • The gas valve, replaced if needed
  • The condensate trap outlet, cleaned
  • The electrodes: dirt, replaced if needed
  • The electrodes' connecting cable
  • The flue system, cleaned or repaired

The same fault on other boilers

Recent boilers show alone the number older ones show beside the code.